The Etest involves placing a plastic strip impregnated with a gradient of an antibiotic on an agar plate that has been inoculated with a specific bacterial strain. The strip diffuses the antibiotic into the agar, creating a gradient. After incubation, a tear-shaped zone of inhibition forms around the strip, and the MIC is read where the edge of this zone intersects the strip.